MBMap Registry
  1. Devices
  2. Líder Balanças
  3. LD1050 LCD

Líder Balanças LD1050 LCD Modbus register map

Digital weighing indicator: net weight and tare, as whole numbers and as floats

  • Official
  • 4 registers
  • Modbus TCP and RTU
  • Revision 1 · 2026-11-08

Official: Written from the manufacturer's documentation, but not tested on a device yet. Check the map against the manufacturer's documentation before you write to a live device. Tested it? Report a test.

Communication

Protocol
Modbus TCP and RTU
Unit ID
1
TCP port
502
Serial
9600 8N1 · 9600 baud, 8 data bits, none parity, 1 stop bit
Byte / word order
CDAB · bytes big-endian, words low first (word swap)
Addresses
0-based

Connection values are defaults: the device may be configured differently.

Map

Registers
4 holding registers
Groups
1
Revision
1 · 2026-11-08
Added
()
File
maps/lider-balancas/ld1050-lcd.mbmap.json · 2 KB · history
SHA-256
8d20df79d29f75489b0c2af65bcb1a3241a805a5b1f4f4d5dcf09871054cfb1e
Manufacturer
liderbalancas.com.br

Sources and notes

Source: Líder Balanças Indicador Digital LD2051 Manual do Usuário v2.5, Modbus chapter (shared with the LD1050 LCD)

  • The Modbus protocol is optional. Modbus RTU or ASCII on RS-232 (F300 = 4 or 5) or RS-485 (F315), and Modbus TCP or RTU over TCP on the LD1050 LCD network board (F300 = 11 or 12). FC03 only. Addresses are 0-based, as sent on the wire; the manual's InduSoft example numbers them from 1 (84 for 0x53).
  • Factory serial settings: 9600 bit/s, 8 data bits, no parity, 1 stop bit (F301/F304, F308, F309). The address (F302) is 1 to 255; the manual gives no default.
  • 32-bit values are sent low word first: the manual's example frames read 500 as 01 F4 00 00 and 0.5 as 00 00 3F 00.
  • The manual is written for the LD2051 and gives the same Modbus registers for the LD1050 LCD. Written from the manual; this map has not been tested on a device.
AreaAddressNameTypeAccessUnitScaleDescription
HR 83 int32 CDAB R Net weight without the decimal point: 0.5 kg with three decimals reads 500
HR 85 int32 CDAB R Tare without the decimal point
HR 87 float32 CDAB R
HR 89 float32 CDAB R

Help improve this map