MBMap Registry
  1. Devices
  2. Raedian
  3. NEO

Raedian NEO Modbus register map

Also covers NEO 7-T5

AC wallbox with RS-485 (Modbus RTU) control

  • Unofficial
  • 14 registers
  • Modbus RTU
  • Revision 1 · 2026-10-18

Unofficial: Copied from an unofficial source and not tested. Read it as a draft and check a value on the real device before you rely on the rest. Check the map against the manufacturer's documentation before you write to a live device. Tested it? Report a test.

Communication

Protocol
Modbus RTU
Unit ID
1
Serial
9600 8N1 · 9600 baud, 8 data bits, none parity, 1 stop bit
Byte / word order
ABCD · bytes big-endian, words high first
Addresses
0-based

Connection values are defaults: the device may be configured differently.

Map

Registers
14 holding registers
Groups
3
Revision
1 · 2026-10-18
Added
()
File
maps/raedian/neo.mbmap.json · 5 KB · history
SHA-256
ee0a69b05e5fe05071a12c6bd7d207ffad569977d26d113d8104b29d0e261f90
Manufacturer
raedian.com

Sources and notes

Source: evcc charger driver for the RAEDIAN AC wallbox, which implements the manufacturer's 'Modbus Protocol RAEDIAN AC Wallbox v0.3'. Not checked against the manufacturer's document

  • Values are read with FC03; the control registers are written with FC06 (16-bit) and FC16 (32-bit).
  • Enable Modbus RTU in the charger's settings first. Serial settings: 9600 baud, 8 data bits, no parity, 1 stop bit; the address is set in the same menu (1 in the examples).
  • Unofficial: taken from a third-party driver, not from the manufacturer's protocol document (Raedian's support page does not publish it).
  • The driver reads the status as a 32-bit word whose byte A1 holds the charging state in bits 6 to 0 and a current-limit flag in bit 7; here they are split into the two registers.
AreaAddressNameTypeAccessUnitScaleDescription
HR 32780 uint16 R Bytes A3 and A2 of the status word at 0x800C
HR 32781 uint16 bits 8–14 R Bits 6 to 0 of byte A1 of the status word
HR 32781 bool bit 15 R Bit 7 of byte A1 of the status word
HR 32784 uint32 ABCD R A ×0.001
HR 32786 uint32 ABCD R A ×0.001
HR 32788 uint32 ABCD R A ×0.001
HR 32790 uint32 ABCD R V ×0.1
HR 32792 uint32 ABCD R V ×0.1
HR 32794 uint32 ABCD R V ×0.1
HR 32796 uint32 ABCD R W
HR 32798 uint32 ABCD R Wh Energy of the current session
HR 33024 uint32 ABCD W A ×0.001 Set in mA; 0 stops charging
HR 33026 uint16 W
HR 33029 uint16 W

Help improve this map