Samsung EHS Mono heat pumps (Gen 6 / Gen 7) Modbus register map

Also covers AE080BXYDEG/EU, AE120BXYDEG/EU, AE140BXYDEG/EU, AE080BXYDGG/EU, AE120BXYDGG/EU, AE140BXYDGG/EU, AE050CXYDEK/EU, AE080CXYDEK/EU, AE120CXYDEK/EU, AE160CXYDEK/EU, AE080CXYDGK/EU, AE120CXYDGK/EU, AE160CXYDGK/EU, AE050CXYBEK/EU, AE080CXYBEK/EU, AE120CXYBEK/EU, AE160CXYBEK/EU, AE080CXYBGK/EU, AE120CXYBGK/EU, AE160CXYBGK/EU

Air-to-water heat pumps read through the MIM-B19N Modbus interface

  • Unofficial
  • 68 registers
  • Modbus RTU
  • Revision 1 · 2026-10-14

Unofficial: Copied from an unofficial source and not tested. Read it as a draft and check a value on the real device before you rely on the rest. Check the map against the manufacturer's documentation before you write to a live device. Tested it? Report a test.

Communication

Protocol
Modbus RTU
Unit ID
2
Serial
9600 8E1 · 9600 baud, 8 data bits, even parity, 1 stop bit
Byte / word order
ABCD · bytes big-endian, words high first
Addresses
0-based

Connection values are defaults: the device may be configured differently.

Map

Registers
68 holding registers
Revision
1 · 2026-10-14
Added
()
File
maps/samsung/ehs-gen6-gen7.mbmap.json · 9 KB · history
SHA-256
2f7e0b6e765b5fb0b9fed4b1ebf52b711a1ea7150c7c52adc013dfc31986a118
Manufacturer
samsung.com

Sources and notes

Source: Warm Energy Labs Heat Pump Modbus Database (MIT licence); tested by them on an AE160CXYDEK/EU

  • Read through the Samsung MIM-B19N Modbus interface module; the source uses unit ID 2.
  • Some values only appear after their message IDs are mapped: registers 6000+ and 7000+ of the interface select which outdoor and indoor values are published at addresses 4-35 and 82-101 (see the source for the list).
  • All registers are holding registers. Values are 16-bit signed.
  • Converted from the Warm Energy database. Writing to a heat pump can damage it: check before you write.
AreaAddressNameTypeAccessUnitScaleDescription
HR 0 int16 R
HR 1 int16 R
HR 2 int16 R
HR 3 int16 RW
HR 4 int16 R °C
HR 5 int16 R
HR 6 int16 R
HR 7 int16 R
HR 8 int16 R
HR 9 int16 R
HR 10 int16 R
HR 11 int16 R
HR 12 int16 R
HR 13 int16 R °C ×0.1
HR 14 int16 R kgf/cm² ×0.1
HR 15 int16 R kgf/cm² ×0.1
HR 16 int16 R °C ×0.1
HR 17 int16 R A ×0.1
HR 18 int16 R °C ×0.1
HR 19 int16 R °C ×0.1
HR 20 int16 R °C ×0.1
HR 21 int16 R °C ×0.1
HR 22 int16 R rpm
HR 23 int16 R
HR 24 int16 R
HR 25 int16 R Hz
HR 26 int16 R Hz
HR 27 int16 R Hz
HR 28 int16 R V
HR 29 int16 R rpm
HR 30 int16 R °C ×0.1
HR 31 int16 R °C ×0.1
HR 32 int16 R °C ×0.1
HR 33 int16 R °C ×0.1
HR 34 int16 R °C ×0.1
HR 35 int16 R °C ×0.1
HR 52 int16 RW
HR 53 int16 RW
HR 63 int16 R
HR 64 int16 R
HR 65 int16 R °C ×0.1
HR 66 int16 R °C ×0.1
HR 68 int16 RW °C ×0.1 Current water outlet setpoint (read-only). Use climate target_temp_register (68) to control flow temperature
HR 72 int16 RW
HR 73 int16 R
HR 74 int16 RW °C ×0.1
HR 75 int16 R °C ×0.1
HR 78 int16 RW
HR 79 int16 RW
HR 82 int16 R
HR 83 int16 R
HR 84 int16 R
HR 85 int16 R %
HR 86 int16 RW
HR 87 int16 R °C ×0.1
HR 89 int16 R °C ×0.1
HR 90 int16 R °C ×0.1
HR 91 int16 R °C ×0.1
HR 92 int16 R °C ×0.1
HR 93 int16 R %
HR 94 int16 R °C ×0.1
HR 95 int16 RW °C ×0.1
HR 96 int16 R °C ×0.1
HR 97 int16 R °C ×0.1
HR 98 int16 R l/min ×0.1
HR 99 int16 R
HR 100 int16 R
HR 101 int16 R