SolarEdge Energy meter (SunSpec 201-204) Modbus register map

Export, import, production or consumption meters connected to a SolarEdge inverter, up to three, through SunSpec meter models. Line-to-line voltages are not supported by the SolarEdge meter

  • Official
  • 261 registers
  • Modbus TCP and RTU
  • Revision 1

Official: Written from the manufacturer's documentation, but not tested on a device yet. Check the map against the manufacturer's documentation before you write to a live device. Tested it? Report a test.

Communication

Protocol
Modbus TCP and RTU
Unit ID
1
TCP port
502
Serial
115200 8N1 · 115200 baud, 8 data bits, none parity, 1 stop bit
Byte / word order
ABCD · bytes big-endian, words high first
Addresses
0-based

Connection values are defaults: the device may be configured differently.

Map

Registers
261 holding registers
Groups
27
Revision
1
Added
()
File
maps/solaredge/energy-meter-sunspec.mbmap.json · 60 KB · history
SHA-256
c24ceeeef0792e1ce9ef3a618d6bde23d08fb9c423f31a51bcc965f9f9451b21
Manufacturer
solaredge.com

Sources and notes

Source: SolarEdge, "SolarEdge Inverters - SunSpec Logging - Technical Note" v2.6 (December 2023), meter model register mapping; SunSpec Alliance information model definitions (github.com/sunspec/models), models 1 and 203

  • SolarEdge energy meters (Modbus meters wired to an inverter), SunSpec meter models 201-204.
  • Meter 1 is at the default position; with Synergy inverters add 50 (2 units) or 70 (3 units) to every address.
  • Only enabled meters can be read: if meters 1 and 3 are enabled they appear as meters 1 and 2.
AreaAddressNameTypeAccessUnitScaleDescription
HR 40121 uint16 R SunSpec ID
HR 40122 uint16 R SunSpec L
HR 40123 string[16] R SunSpec Mn
HR 40139 string[16] R SunSpec Md
HR 40155 string[8] R SunSpec Opt
HR 40163 string[8] R SunSpec Vr
HR 40171 string[16] R SunSpec SN
HR 40187 uint16 R SunSpec DA. This point is mandatory for all SunSpec RTU devices and, for those devices, they must support values from 1-247.
HR 40188 uint16 R SunSpec ID. 201 = single phase, 202 = split phase, 203 = three phase wye, 204 = three phase delta
HR 40189 uint16 R SunSpec L
HR 40190 int16 R A ×10^Meter 1 Current scale factor SunSpec A
HR 40191 int16 R A ×10^Meter 1 Current scale factor SunSpec AphA
HR 40192 int16 R A ×10^Meter 1 Current scale factor SunSpec AphB
HR 40193 int16 R A ×10^Meter 1 Current scale factor SunSpec AphC
HR 40194 int16 R SunSpec A_SF
HR 40195 int16 R V ×10^Meter 1 Voltage scale factor SunSpec PhV
HR 40196 int16 R V ×10^Meter 1 Voltage scale factor SunSpec PhVphA
HR 40197 int16 R V ×10^Meter 1 Voltage scale factor SunSpec PhVphB
HR 40198 int16 R V ×10^Meter 1 Voltage scale factor SunSpec PhVphC
HR 40199 int16 R V ×10^Meter 1 Voltage scale factor SunSpec PPV. Not supported by the SolarEdge meter through SunSpec
HR 40200 int16 R V ×10^Meter 1 Voltage scale factor SunSpec PhVphAB
HR 40201 int16 R V ×10^Meter 1 Voltage scale factor SunSpec PhVphBC
HR 40202 int16 R V ×10^Meter 1 Voltage scale factor SunSpec PhVphCA
HR 40203 int16 R SunSpec V_SF
HR 40204 int16 R Hz ×10^Meter 1 Frequency scale factor SunSpec Hz
HR 40205 int16 R SunSpec Hz_SF
HR 40206 int16 R W ×10^Meter 1 Real Power scale factor SunSpec W
HR 40207 int16 R W ×10^Meter 1 Real Power scale factor SunSpec WphA
HR 40208 int16 R W ×10^Meter 1 Real Power scale factor SunSpec WphB
HR 40209 int16 R W ×10^Meter 1 Real Power scale factor SunSpec WphC
HR 40210 int16 R SunSpec W_SF
HR 40211 int16 R VA ×10^Meter 1 Apparent Power scale factor SunSpec VA
HR 40212 int16 R VA ×10^Meter 1 Apparent Power scale factor SunSpec VAphA
HR 40213 int16 R VA ×10^Meter 1 Apparent Power scale factor SunSpec VAphB
HR 40214 int16 R VA ×10^Meter 1 Apparent Power scale factor SunSpec VAphC
HR 40215 int16 R SunSpec VA_SF
HR 40216 int16 R var ×10^Meter 1 Reactive Power scale factor SunSpec VAR
HR 40217 int16 R var ×10^Meter 1 Reactive Power scale factor SunSpec VARphA
HR 40218 int16 R var ×10^Meter 1 Reactive Power scale factor SunSpec VARphB
HR 40219 int16 R var ×10^Meter 1 Reactive Power scale factor SunSpec VARphC
HR 40220 int16 R SunSpec VAR_SF
HR 40221 int16 R % ×10^Meter 1 Power Factor scale factor SunSpec PF
HR 40222 int16 R % ×10^Meter 1 Power Factor scale factor SunSpec PFphA
HR 40223 int16 R % ×10^Meter 1 Power Factor scale factor SunSpec PFphB
HR 40224 int16 R % ×10^Meter 1 Power Factor scale factor SunSpec PFphC
HR 40225 int16 R SunSpec PF_SF
HR 40226 uint32 ABCD R Wh ×10^Meter 1 Real Energy scale factor SunSpec TotWhExp
HR 40228 uint32 ABCD R Wh ×10^Meter 1 Real Energy scale factor SunSpec TotWhExpPhA
HR 40230 uint32 ABCD R Wh ×10^Meter 1 Real Energy scale factor SunSpec TotWhExpPhB
HR 40232 uint32 ABCD R Wh ×10^Meter 1 Real Energy scale factor SunSpec TotWhExpPhC
HR 40234 uint32 ABCD R Wh ×10^Meter 1 Real Energy scale factor SunSpec TotWhImp
HR 40236 uint32 ABCD R Wh ×10^Meter 1 Real Energy scale factor SunSpec TotWhImpPhA
HR 40238 uint32 ABCD R Wh ×10^Meter 1 Real Energy scale factor SunSpec TotWhImpPhB
HR 40240 uint32 ABCD R Wh ×10^Meter 1 Real Energy scale factor SunSpec TotWhImpPhC
HR 40242 int16 R SunSpec TotWh_SF
HR 40243 uint32 ABCD R VAh ×10^Meter 1 Apparent Energy scale factor SunSpec TotVAhExp
HR 40245 uint32 ABCD R VAh ×10^Meter 1 Apparent Energy scale factor SunSpec TotVAhExpPhA
HR 40247 uint32 ABCD R VAh ×10^Meter 1 Apparent Energy scale factor SunSpec TotVAhExpPhB
HR 40249 uint32 ABCD R VAh ×10^Meter 1 Apparent Energy scale factor SunSpec TotVAhExpPhC
HR 40251 uint32 ABCD R VAh ×10^Meter 1 Apparent Energy scale factor SunSpec TotVAhImp
HR 40253 uint32 ABCD R VAh ×10^Meter 1 Apparent Energy scale factor SunSpec TotVAhImpPhA
HR 40255 uint32 ABCD R VAh ×10^Meter 1 Apparent Energy scale factor SunSpec TotVAhImpPhB
HR 40257 uint32 ABCD R VAh ×10^Meter 1 Apparent Energy scale factor SunSpec TotVAhImpPhC
HR 40259 int16 R SunSpec TotVAh_SF
HR 40260 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhImpQ1
HR 40262 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhImpQ1PhA
HR 40264 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhImpQ1PhB
HR 40266 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhImpQ1PhC
HR 40268 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhImpQ2
HR 40270 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhImpQ2PhA
HR 40272 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhImpQ2PhB
HR 40274 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhImpQ2PhC
HR 40276 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhExpQ3
HR 40278 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhExpQ3PhA
HR 40280 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhExpQ3PhB
HR 40282 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhExpQ3PhC
HR 40284 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhExpQ4
HR 40286 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhExpQ4PhA
HR 40288 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhExpQ4PhB
HR 40290 uint32 ABCD R varh ×10^Meter 1 Reactive Energy scale factor SunSpec TotVArhExpQ4PhC
HR 40292 int16 R SunSpec TotVArh_SF
HR 40294 bool bit 2 R SunSpec Evt bit 2
HR 40294 bool bit 3 R SunSpec Evt bit 3
HR 40294 bool bit 4 R SunSpec Evt bit 4
HR 40294 bool bit 5 R SunSpec Evt bit 5
HR 40294 bool bit 6 R SunSpec Evt bit 6
HR 40294 bool bit 7 R SunSpec Evt bit 7
HR 40295 uint16 R SunSpec ID
HR 40296 uint16 R SunSpec L
HR 40297 string[16] R SunSpec Mn
HR 40313 string[16] R SunSpec Md
HR 40329 string[8] R SunSpec Opt
HR 40337 string[8] R SunSpec Vr
HR 40345 string[16] R SunSpec SN
HR 40361 uint16 R SunSpec DA. This point is mandatory for all SunSpec RTU devices and, for those devices, they must support values from 1-247.
HR 40362 uint16 R SunSpec ID. 201 = single phase, 202 = split phase, 203 = three phase wye, 204 = three phase delta
HR 40363 uint16 R SunSpec L
HR 40364 int16 R A ×10^Meter 2 Current scale factor SunSpec A
HR 40365 int16 R A ×10^Meter 2 Current scale factor SunSpec AphA
HR 40366 int16 R A ×10^Meter 2 Current scale factor SunSpec AphB