Sungrow SH series hybrid inverters Modbus register map

Also covers SH3K6, SH4K6, SH5K-20, SH5K-V13, SH3K6-30, SH4K6-30, SH5K-30, SH3.0RS, SH3.6RS, SH4.0RS, SH5.0RS, SH6.0RS, SH5.0RT, SH6.0RT, SH8.0RT, SH10RT

Residential hybrid inverters (SH-K, SH-RS, SH-RT)

  • Official
  • 155 registers
  • Modbus TCP and RTU
  • Revision 1 · 2026-10-14
  • Identity: model, firmware, serial number

Official: Written from the manufacturer's documentation, but not tested on a device yet. Check the map against the manufacturer's documentation before you write to a live device. Tested it? Report a test.

Communication

Protocol
Modbus TCP and RTU
Unit ID
1
TCP port
502
Serial
9600 8N1 · 9600 baud, 8 data bits, none parity, 1 stop bit
Byte / word order
CDAB · bytes big-endian, words low first (word swap)
Addresses
1-based · wire address = address − 1

Connection values are defaults: the device may be configured differently.

Map

Registers
53 holding registers, 102 input registers
Groups
16
Revision
1 · 2026-10-14
Added
()
File
maps/sungrow/sh-hybrid.mbmap.json · 31 KB · history
SHA-256
8c7430f240707c7da1c9d7189da95eb7f1f1f9392b35cd64a2595f98e5da4f9a
Manufacturer
sungrowpower.com

Device identity

What a tool can read to check that this map fits the connected device (SPEC.md section 4.7). Registers with a role are read like any other register.

Registers
RoleRegisterAddressTypeValues
Firmware ARM software version input 4954 string[15]
Serial number Serial number input 4990 string[10]
Model Device type code input 5000 uint16 0x0D03 = SH5K-V13, 0x0D06 = SH3K6, 0x0D07 = SH4K6, +13 more

Sources and notes

Source: Sungrow, Communication Protocol of Residential Hybrid Inverter V1.0.23 (TI_20211231)

  • Addresses are the protocol addresses of the manual; the wire address is one less (address_base 1).
  • Read-only data are input registers (FC04); settings are holding registers (FC03/06/16). Input 5000 and holding 5000 are different registers.
  • 32-bit values are sent low word first.
  • The 15-minute and daily/monthly/yearly history tables (6100-6826) are not listed here.
  • Newer firmware and models (SH-RT V2, SH-T) have more registers that this document does not cover.
AreaAddressNameTypeAccessUnitScaleDescription
IR 4950 uint32 CDAB R
IR 4952 uint32 CDAB R
IR 4954 string[15] R
IR 4969 string[15] R
IR 4990 string[10] R
IR 5000 uint16 R
IR 5001 uint16 R kW ×0.1
IR 5002 uint16 R
IR 5003 uint16 R kWh ×0.1 PV generation plus battery discharge
IR 5004 uint32 CDAB R kWh ×0.1 PV generation plus battery discharge
IR 5008 int16 R °C ×0.1
IR 5011 uint16 R V ×0.1
IR 5012 uint16 R A ×0.1
IR 5013 uint16 R V ×0.1
IR 5014 uint16 R A ×0.1
IR 5017 uint32 CDAB R W PV power
IR 5019 uint16 R V ×0.1 Phase or line voltage, depending on the output type
IR 5020 uint16 R V ×0.1 Phase or line voltage, depending on the output type
IR 5021 uint16 R V ×0.1 Phase or line voltage, depending on the output type
IR 5033 int32 CDAB R var
IR 5035 int16 R ×0.001 Positive = leading, negative = lagging
IR 5036 uint16 R Hz ×0.1
IR 5622 uint16 R W ×10 Only on SH5.0RT/SH6.0RT/SH8.0RT/SH10RT and SH3.0RS-SH6.0RS
IR 5623 uint16 R W ×10 Only on SH5.0RT/SH6.0RT/SH8.0RT/SH10RT and SH3.0RS-SH6.0RS
IR 5628 uint16 R W ×100 Only on SH5.0RT/SH6.0RT/SH8.0RT/SH10RT and SH3.0RS-SH6.0RS
IR 5635 uint16 R A Only on SH5.0RT/SH6.0RT/SH8.0RT/SH10RT and SH3.0RS-SH6.0RS
IR 5636 uint16 R A Only on SH5.0RT/SH6.0RT/SH8.0RT/SH10RT and SH3.0RS-SH6.0RS
IR 13000 uint16 R
IR 13001 bool bit 0 R Running state, bit 0
IR 13001 bool bit 1 R Running state, bit 1
IR 13001 bool bit 2 R Running state, bit 2
IR 13001 bool bit 3 R Running state, bit 3
IR 13001 bool bit 4 R Running state, bit 4
IR 13001 bool bit 5 R Running state, bit 5
IR 13001 bool bit 7 R Running state, bit 7: negative load power (retrofitted system)
IR 13002 uint16 R kWh ×0.1
IR 13003 uint32 CDAB R kWh ×0.1
IR 13005 uint16 R kWh ×0.1 The manual gives the unit as 0.1 kW
IR 13006 uint32 CDAB R kWh ×0.1
IR 13008 int32 CDAB R W
IR 13010 int32 CDAB R W Negative when importing
IR 13012 uint16 R kWh ×0.1
IR 13013 uint32 CDAB R kWh ×0.1
IR 13015 uint32 CDAB R kg ×0.1
IR 13017 uint16 R kWh ×0.1
IR 13018 uint32 CDAB R kWh ×0.1
IR 13020 uint16 R V ×0.1
IR 13021 uint16 R A ×0.1
IR 13022 uint16 R W
IR 13023 uint16 R % ×0.1
IR 13024 uint16 R % ×0.1
IR 13025 int16 R °C ×0.1
IR 13026 uint16 R kWh ×0.1
IR 13027 uint32 CDAB R kWh ×0.1
IR 13029 uint16 R % ×0.1
IR 13030 uint16 R
IR 13031 int16 R A ×0.1
IR 13032 int16 R A ×0.1
IR 13033 int16 R A ×0.1
IR 13034 int32 CDAB R W
IR 13036 uint16 R kWh ×0.1
IR 13037 uint32 CDAB R kWh ×0.1
IR 13039 uint16 R ×0.1 kWh for Li-ion, Ah for lead-acid; Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30
IR 13040 uint16 R kWh ×0.1
IR 13041 uint32 CDAB R kWh ×0.1
IR 13043 uint16 R
IR 13045 uint16 R kWh ×0.1
IR 13046 uint32 CDAB R kWh ×0.1
IR 13050 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13052 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13054 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13056 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13058 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13060 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13062 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13064 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13066 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13068 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13070 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13072 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13074 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13076 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13078 uint32 CDAB R Bit field; see appendix 1.3 of the protocol for the fault codes
IR 13100 uint16 R Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30
IR 13101 uint16 R A Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30
IR 13102 uint16 R A Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30
IR 13103 uint16 R Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30
IR 13104 uint16 R Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30
IR 13105 uint16 R Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30
IR 13106 uint16 R Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30
IR 13107 uint16 R % Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30
IR 13108 uint16 R % Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30
IR 13109 uint16 R A ×0.1 Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30
IR 13110 uint16 R V ×0.01 Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30
IR 13111 uint16 R Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30
IR 13112 uint16 R Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30; unit not given in the manual
IR 13113 uint16 R Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30; unit not given in the manual
IR 13114 uint16 R Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30; unit not given in the manual
IR 13115 uint16 R Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30; unit not given in the manual
IR 13116 int16 R Only on SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30 and SH4K6-30; unit not given in the manual