MBMap Registry
  1. Devices
  2. Teltonika
  3. RUT241

Teltonika RUT241 Modbus register map

LTE router: system, mobile data and I/O values over the Modbus server

  • Official
  • 39 registers
  • Revision 2 · 2026-11-10
  • Identity: serial number

Official: Written from the manufacturer's documentation, but not tested on a device yet. Check the map against the manufacturer's documentation before you write to a live device. Tested it? Report a test.

Communication

Protocol
Modbus TCP and RTUdefault
Unit ID
1
TCP port
502default
Serial
9600 8N1 · 9600 baud, 8 data bits, none parity, 1 stop bit
Byte / word order
ABCD · bytes big-endian, words high first
Addresses
0-based

Connection values are defaults: the device may be configured differently.

Map

Registers
39 holding registers
Groups
4
Revision
2 · 2026-11-10
Added
()
File
maps/teltonika/rut241.mbmap.json · 10 KB · history
SHA-256
2b5e4a86b734daadf2d7c229335c8fd2113250fb7057fad2fef3ca92301e8e2f
Manufacturer
teltonika-networks.com

Device identity

What a tool can read to check that this map fits the connected device (SPEC.md section 4.7). Registers with a role are read like any other register.

Registers
RoleRegisterAddressTypeValues
Serial number Serial number holding 39 string[16]

Sources and notes

Source: Teltonika Networks Wiki, "RUT241 Modbus"; https://wiki.teltonika-networks.com/view/RUT241_Modbus

  • Teltonika RUT241 LTE router: the Modbus TCP server and the serial Modbus server both answer with the same system values. The registers are holding registers (function 3 to read, 6 and 16 to write).
  • The manual lists a register address (0-based, as sent on the bus) and a register number (address + 1). This map uses the address.
  • Text values take 2 characters per register. Numbers take 2 registers; the manual gives no word order, so big is assumed.
  • Mobile data counters are in bytes, kilobytes or megabytes, as chosen by the Mobile data type setting of the Modbus server.
  • The server is off by default. Factory settings: TCP port 502, device ID 1 (0 answers to any ID), serial 9600 baud, 8 data bits, no parity, 1 stop bit.
  • With 'Enable custom register block' on, registers from 1025 onward are a user-defined block that is not in this map.
  • Left out because the manual is not clear: Mobile data received last month (SIM1), Mobile data sent last month (SIM1), Mobile data received last week (SIM1), Mobile data sent last week (SIM1), Change APN (length not fixed).
AreaAddressNameTypeAccessUnitScaleDescription
HR 1 uint32 ABCD R System uptime
HR 3 int32 ABCD R dBm RSSI
HR 5 int32 ABCD R °C ×0.1
HR 7 string[16] RW
HR 23 string[16] R
HR 39 string[16] R
HR 55 string[16] R
HR 71 string[16] RW
HR 87 string[16] R
HR 103 string[16] R
HR 119 string[16] R
HR 139 uint32 ABCD R The manual calls it an 8-bit unsigned integer but gives two registers; read as one 32-bit number
HR 185 uint32 ABCD R
HR 187 uint32 ABCD R
HR 189 uint32 ABCD R
HR 191 uint32 ABCD R
HR 193 uint32 ABCD R
HR 195 uint32 ABCD R
HR 197 uint32 ABCD R
HR 199 uint32 ABCD R
HR 203 uint16 W Turns WiFi ON or OFF
HR 204 uint16 W Turns mobile data connection ON or OFF
HR 205 uint16 R Index of the active SIM
HR 206 uint16 W Write 1 to reboot the device
HR 292 uint32 ABCD R
HR 294 uint32 ABCD R
HR 296 uint32 ABCD R
HR 298 uint32 ABCD R
HR 324 uint16 R
HR 325 uint16 RW
HR 328 string[8] R
HR 348 string[16] R
HR 364 uint32 ABCD R
HR 366 string[12] R
HR 378 string[12] R
HR 390 uint16 W Turns 2.4GHz WiFi ON or OFF
HR 394 uint32 ABCD RW
HR 396 uint16 W Sends an SMS with content defined in Add SMS (397) register
HR 397 string[90] RW

Help improve this map