  "$schema": "https://raw.githubusercontent.com/nobrega8/mbmap-library/main/schema/mbmap-2.schema.json",
  "mbmap": 2,
  "vendor": "Schneider Electric",
  "model": "ION8800",
  "models": [
    "ION8800",
    "Powerlogic ION8800"
  ],
  "vendor_website": "se.com",
  "description": "Revenue meter (default Modbus register map)",
  "revision": 3,
  "revised": "2026-10-18",
  "source": "Schneider Electric, Modbus protocol and register map for ION devices, 70022-0124-01 (08/2011), section Modbus register map ION8800",
  "sources": [
    {
      "title": "PowerLogic ION Meters Modbus Protocol and Register Map",
      "version": "70022-0124-01",
      "date": "2011-08",
      "url": "https://www.se.com/us/en/download/document/70022-0124-01/",
      "note": "Modbus Slave module registers, section ION8800"
    }
  ],
  "notes": [
    "The register map of an ION meter has a part you configure (the Modbus Slave modules) and a fixed part. This map is the default Modbus Slave module map of the template revisions named by the manufacturer; if the meter has a custom framework, the registers can be elsewhere.",
    "Addresses are the 4xxxx register numbers of the manual minus 40000, as sent on the wire (register 40011 is address 10). Values are read with FC03; FC16 writes the registers marked read/write.",
    "32-bit values have the high-order register first. A value shown with a scale is the register divided by the scaling of the module (11982 with scaling 10 is 1198.2). The units are inferred from the register labels.",
    "Unmapped registers between blocks read as 0xFFFF.",
    "Not in this map: the 32-bit modulus-10000 (M10K) energy registers, and the common Modbus registers for setup and control.",
    "Default template revisions: This table outlines the default data registers available on the ION8800 power meters. This register map is applicable to the following template revisions:  8800C_V330_FAC_V3.3.0.0.3  8800B_V330_FAC_V3.3.0.0.3  8800A_V330_FAC_V3.3.0.0.3 number registers enabled"
  ],
  "byte_order": "big",
  "word_order": "big",
  "address_base": 0,
  "x_status": "official",
  "registers": [
    {
      "name": "Uln 1 (40011)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 11,
      "type": "uint16",
      "access": "R",
      "unit": "V",
      "scale": 0.1
    },
    {
      "name": "Uln 2 (40012)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 12,
      "type": "uint16",
      "access": "R",
      "unit": "V",
      "scale": 0.1
    },
    {
      "name": "Uln 3 (40013)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 13,
      "type": "uint16",
      "access": "R",
      "unit": "V",
      "scale": 0.1
    },
    {
      "name": "Uln avg (40014)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 14,
      "type": "uint16",
      "access": "R",
      "unit": "V",
      "scale": 0.1
    },
    {
      "name": "Ull 12 (40015)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 15,
      "type": "uint16",
      "access": "R",
      "unit": "V",
      "scale": 0.1
    },
    {
      "name": "Ull 23 (40016)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 16,
      "type": "uint16",
      "access": "R",
      "unit": "V",
      "scale": 0.1
    },
    {
      "name": "Ull 31 (40017)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 17,
      "type": "uint16",
      "access": "R",
      "unit": "V",
      "scale": 0.1
    },
    {
      "name": "Ull avg (40018)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 18,
      "type": "uint16",
      "access": "R",
      "unit": "V",
      "scale": 0.1
    },
    {
      "name": "I1 (40019)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 19,
      "type": "uint16",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "I2 (40020)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 20,
      "type": "uint16",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "I3 (40021)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 21,
      "type": "uint16",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "I avg (40022)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 22,
      "type": "uint16",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "U unbal (40023)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 23,
      "type": "uint16",
      "access": "R",
      "unit": "%",
      "scale": 0.1
    },
    {
      "name": "I unbal (40024)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 24,
      "type": "uint16",
      "access": "R",
      "unit": "%",
      "scale": 0.1
    },
    {
      "name": "Freq (40025)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 25,
      "type": "uint16",
      "access": "R",
      "unit": "Hz",
      "scale": 0.1
    },
    {
      "name": "I4 (40026)",
      "group": "Volts/Amps/Freq",
      "area": "holding",
      "address": 26,
      "type": "uint16",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "kW 1 (40027)",
      "group": "Power/PF",
      "area": "holding",
      "address": 27,
      "type": "int32",
      "access": "R",
      "unit": "kW",
      "scale": 0.1
    },
    {
      "name": "kW 2 (40029)",
      "group": "Power/PF",
      "area": "holding",
      "address": 29,
      "type": "int32",
      "access": "R",
      "unit": "kW",
      "scale": 0.1
    },
    {
      "name": "kW 3 (40031)",
      "group": "Power/PF",
      "area": "holding",
      "address": 31,
      "type": "int32",
      "access": "R",
      "unit": "kW",
      "scale": 0.1
    },
    {
      "name": "kW tot (40033)",
      "group": "Power/PF",
      "area": "holding",
      "address": 33,
      "type": "int32",
      "access": "R",
      "unit": "kW",
      "scale": 0.1
    },
    {
      "name": "kVAR 1 (40035)",
      "group": "Power/PF",
      "area": "holding",
      "address": 35,
      "type": "int32",
      "access": "R",
      "unit": "kvar",
      "scale": 0.1
    },
    {
      "name": "kVAR 2 (40037)",
      "group": "Power/PF",
      "area": "holding",
      "address": 37,
      "type": "int32",
      "access": "R",
      "unit": "kvar",
      "scale": 0.1
    },
    {
      "name": "kVAR 3 (40039)",
      "group": "Power/PF",
      "area": "holding",
      "address": 39,
      "type": "int32",
      "access": "R",
      "unit": "kvar",
      "scale": 0.1
    },
    {
      "name": "kVAR tot (40041)",
      "group": "Power/PF",
      "area": "holding",
      "address": 41,
      "type": "int32",
      "access": "R",
      "unit": "kvar",
      "scale": 0.1
    },
    {
      "name": "kVA 1 (40043)",
      "group": "Power/PF",
      "area": "holding",
      "address": 43,
      "type": "int32",
      "access": "R",
      "unit": "kVA",
      "scale": 0.1
    },
    {
      "name": "kVA 2 (40045)",
      "group": "Power/PF",
      "area": "holding",
      "address": 45,
      "type": "int32",
      "access": "R",
      "unit": "kVA",
      "scale": 0.1
    },
    {
      "name": "kVA 3 (40047)",
      "group": "Power/PF",
      "area": "holding",
      "address": 47,
      "type": "int32",
      "access": "R",
      "unit": "kVA",
      "scale": 0.1
    },
    {
      "name": "kVA tot (40049)",
      "group": "Power/PF",
      "area": "holding",
      "address": 49,
      "type": "int32",
      "access": "R",
      "unit": "kVA",
      "scale": 0.1
    },
    {
      "name": "PF sign 1 (40051)",
      "group": "Power/PF",
      "area": "holding",
      "address": 51,
      "type": "int32",
      "access": "R",
      "scale": 0.1
    },
    {
      "name": "PF sign 2 (40053)",
      "group": "Power/PF",
      "area": "holding",
      "address": 53,
      "type": "int32",
      "access": "R",
      "scale": 0.1
    },
    {
      "name": "PF sign 3 (40055)",
      "group": "Power/PF",
      "area": "holding",
      "address": 55,
      "type": "int32",
      "access": "R",
      "scale": 0.1
    },
    {
      "name": "PF sign tot (40057)",
      "group": "Power/PF",
      "area": "holding",
      "address": 57,
      "type": "int32",
      "access": "R",
      "scale": 0.1
    },
    {
      "name": "Ull avg mx (40059)",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 59,
      "type": "int32",
      "access": "R",
      "unit": "V",
      "scale": 0.1
    },
    {
      "name": "I avg mx (40061)",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 61,
      "type": "int32",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "kW tot mx (40063)",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 63,
      "type": "int32",
      "access": "R",
      "unit": "kW",
      "scale": 0.1
    },
    {
      "name": "kVAR tot mx (40065)",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 65,
      "type": "int32",
      "access": "R",
      "unit": "kvar",
      "scale": 0.1
    },
    {
      "name": "kVA tot mx (40067)",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 67,
      "type": "int32",
      "access": "R",
      "unit": "kVA",
      "scale": 0.1
    },
    {
      "name": "Freq mx (40069)",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 69,
      "type": "int32",
      "access": "R",
      "unit": "Hz",
      "scale": 0.1
    },
    {
      "name": "Ull avg mn",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 71,
      "type": "int32",
      "access": "R",
      "unit": "V",
      "scale": 0.1
    },
    {
      "name": "I avg mn (40073)",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 73,
      "type": "int32",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "Freq mn (40075)",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 75,
      "type": "int32",
      "access": "R",
      "unit": "Hz",
      "scale": 0.1
    },
    {
      "name": "kW sd del-rec",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 77,
      "type": "int32",
      "access": "R",
      "unit": "kW",
      "scale": 0.1
    },
    {
      "name": "kVA sd del+rec",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 79,
      "type": "int32",
      "access": "R",
      "unit": "kVA",
      "scale": 0.1
    },
    {
      "name": "kVAR sd del-rec",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 81,
      "type": "int32",
      "access": "R",
      "unit": "kvar",
      "scale": 0.1
    },
    {
      "name": "kW sd mx d-r",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 83,
      "type": "int32",
      "access": "R",
      "unit": "kW",
      "scale": 0.1
    },
    {
      "name": "kVA sd mx d+r",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 85,
      "type": "int32",
      "access": "R",
      "unit": "kVA",
      "scale": 0.1
    },
    {
      "name": "kVAR sd mx d-r",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 87,
      "type": "int32",
      "access": "R",
      "unit": "kvar",
      "scale": 0.1
    },
    {
      "name": "Phase Rev (40089)",
      "group": "Min/Max/Demand",
      "area": "holding",
      "address": 89,
      "type": "int32",
      "access": "R",
      "scale": 0.1
    },
    {
      "name": "I1 (40150)",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 150,
      "type": "uint16",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "I2 (40151)",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 151,
      "type": "uint16",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "I3 (40152)",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 152,
      "type": "uint16",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "I4 (40153)",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 153,
      "type": "uint16",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "I avg (40155)",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 155,
      "type": "uint16",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "I avg mn (40156)",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 156,
      "type": "uint16",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "I avg mx (40157)",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 157,
      "type": "uint16",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "I avg mean 1",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 158,
      "type": "uint16",
      "access": "R",
      "unit": "A",
      "scale": 0.1
    },
    {
      "name": "Freq (40159)",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 159,
      "type": "uint16",
      "access": "R",
      "unit": "Hz",
      "scale": 0.1
    },
    {
      "name": "Freq mn (40160)",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 160,
      "type": "uint16",
      "access": "R",
      "unit": "Hz",
      "scale": 0.1
    },
    {
      "name": "Freq mx (40161)",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 161,
      "type": "uint16",
      "access": "R",
      "unit": "Hz",
      "scale": 0.1
    },
    {
      "name": "Freq mean 1",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 162,
      "type": "uint16",
      "access": "R",
      "unit": "Hz",
      "scale": 0.1
    },
    {
      "name": "U unbal (40163)",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 163,
      "type": "uint16",
      "access": "R",
      "unit": "%",
      "scale": 0.1
    },
    {
      "name": "I unbal (40164)",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 164,
      "type": "uint16",
      "access": "R",
      "unit": "%",
      "scale": 0.1
    },
    {
      "name": "Phase Rev (40165)",
      "group": "Amp/freq/unbal",
      "area": "holding",
      "address": 165,
      "type": "uint16",
      "access": "R",
      "scale": 0.1
    },
    {
      "name": "Uln 1 (40166)",
      "group": "Volts",
      "area": "holding",
      "address": 166,
      "type": "uint32",
      "access": "R"
    },
    {
      "name": "Uln 2 (40168)",
      "group": "Volts",
      "area": "holding",
      "address": 168,
      "type": "uint32",
      "access": "R"
    },
    {
      "name": "Uln 3 (40170)",
      "group": "Volts",
      "area": "holding",
      "address": 170,
      "type": "uint32",
      "access": "R"
    },
    {
      "name": "Uln avg (40172)",
      "group": "Volts",
      "area": "holding",
      "address": 172,
      "type": "uint32",
      "access": "R"
    },
    {
      "name": "Uln avg mx",
      "group": "Volts",
      "area": "holding",
      "address": 174,
      "type": "uint32",
      "access": "R"
    },
    {
      "name": "Ull 12 (40178)",
      "group": "Volts",
      "area": "holding",
      "address": 178,
      "type": "uint32",
      "access": "R"
    },
    {
      "name": "Ull 23 (40180)",
      "group": "Volts",
      "area": "holding",
      "address": 180,
      "type": "uint32",
      "access": "R"
    },
    {
      "name": "Ull 31 (40182)",
      "group": "Volts",
      "area": "holding",
      "address": 182,
      "type": "uint32",
      "access": "R"
    },
    {
      "name": "Ull avg (40184)",
      "group": "Volts",
      "area": "holding",
      "address": 184,
      "type": "uint32",
      "access": "R"
    },
    {
      "name": "Ull avg mx (40186)",
      "group": "Volts",
      "area": "holding",
      "address": 186,
      "type": "uint32",
      "access": "R"
    },
    {
      "name": "Ull avg mean 1",
      "group": "Volts",
      "area": "holding",
      "address": 188,
      "type": "uint32",
      "access": "R"
    },
    {
      "name": "kW 1 (40198)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 198,
      "type": "int32",
      "access": "R",
      "unit": "kW",
      "scale": 0.001
    },
    {
      "name": "kW 2 (40200)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 200,
      "type": "int32",
      "access": "R",
      "unit": "kW",
      "scale": 0.001
    },
    {
      "name": "kW 3 (40202)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 202,
      "type": "int32",
      "access": "R",
      "unit": "kW",
      "scale": 0.001
    },
    {
      "name": "kW tot (40204)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 204,
      "type": "int32",
      "access": "R",
      "unit": "kW",
      "scale": 0.001
    },
    {
      "name": "kW tot mx (40206)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 206,
      "type": "int32",
      "access": "R",
      "unit": "kW",
      "scale": 0.001
    },
    {
      "name": "kVAR 1 (40208)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 208,
      "type": "int32",
      "access": "R",
      "unit": "kvar",
      "scale": 0.001
    },
    {
      "name": "kVAR 2 (40210)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 210,
      "type": "int32",
      "access": "R",
      "unit": "kvar",
      "scale": 0.001
    },
    {
      "name": "kVAR 3 (40212)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 212,
      "type": "int32",
      "access": "R",
      "unit": "kvar",
      "scale": 0.001
    },
    {
      "name": "kVAR tot (40214)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 214,
      "type": "int32",
      "access": "R",
      "unit": "kvar",
      "scale": 0.001
    },
    {
      "name": "kVAR tot mx (40216)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 216,
      "type": "int32",
      "access": "R",
      "unit": "kvar",
      "scale": 0.001
    },
    {
      "name": "kVA 1 (40218)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 218,
      "type": "int32",
      "access": "R",
      "unit": "kVA",
      "scale": 0.001
    },
    {
      "name": "kVA 2 (40220)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 220,
      "type": "int32",
      "access": "R",
      "unit": "kVA",
      "scale": 0.001
    },
    {
      "name": "kVA 3 (40222)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 222,
      "type": "int32",
      "access": "R",
      "unit": "kVA",
      "scale": 0.001
    },
    {
      "name": "kVA tot (40224)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 224,
      "type": "int32",
      "access": "R",
      "unit": "kVA",
      "scale": 0.001
    },
    {
      "name": "kVA tot mx (40226)",
      "group": "kW/kVAr/kVA",
      "area": "holding",
      "address": 226,
      "type": "int32",
      "access": "R",
      "unit": "kVA",
      "scale": 0.001
    },
    {
      "name": "kWh del",
      "group": "kWh/kVArh",
      "area": "holding",
      "address": 230,
      "type": "int32",
      "access": "R",
      "unit": "kWh"
    },
    {
      "name": "kWh rec",
      "group": "kWh/kVArh",
      "area": "holding",
      "address": 232,
      "type": "int32",
      "access": "R",
      "unit": "kWh"
    },
    {
      "name": "kVARh del",
      "group": "kWh/kVArh",
      "area": "holding",
      "address": 234,
      "type": "int32",
      "access": "R",
      "unit": "kvarh"
    },
    {
      "name": "kVARh rec",
      "group": "kWh/kVArh",
      "area": "holding",
      "address": 236,
      "type": "int32",
      "access": "R",
      "unit": "kvarh"
    },
    {
      "name": "kVAh del+rec",
      "group": "kWh/kVArh",
      "area": "holding",
      "address": 238,
      "type": "int32",
      "access": "R",
      "unit": "kVAh"
    },
    {
      "name": "PF sign 1 (40262)",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 262,
      "type": "int16",
      "access": "R",
      "scale": 0.01
    },
    {
      "name": "PF sign 2 (40263)",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 263,
      "type": "int16",
      "access": "R",
      "scale": 0.01
    },
    {
      "name": "PF sign 3 (40264)",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 264,
      "type": "int16",
      "access": "R",
      "scale": 0.01
    },
    {
      "name": "PF sign tot (40265)",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 265,
      "type": "int16",
      "access": "R",
      "scale": 0.01
    },
    {
      "name": "U1 THD mx",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 266,
      "type": "int16",
      "access": "R",
      "unit": "%",
      "scale": 0.01
    },
    {
      "name": "U2 THD mx",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 267,
      "type": "int16",
      "access": "R",
      "unit": "%",
      "scale": 0.01
    },
    {
      "name": "U3 THD mx",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 268,
      "type": "int16",
      "access": "R",
      "unit": "%",
      "scale": 0.01
    },
    {
      "name": "I1 THD mx",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 269,
      "type": "int16",
      "access": "R",
      "unit": "%",
      "scale": 0.01
    },
    {
      "name": "I2 THD mx",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 270,
      "type": "int16",
      "access": "R",
      "unit": "%",
      "scale": 0.01
    },
    {
      "name": "I3 THD mx",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 271,
      "type": "int16",
      "access": "R",
      "unit": "%",
      "scale": 0.01
    },
    {
      "name": "I1 K Factor",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 272,
      "type": "int16",
      "access": "R",
      "unit": "A",
      "scale": 0.01
    },
    {
      "name": "I2 K Factor",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 273,
      "type": "int16",
      "access": "R",
      "unit": "A",
      "scale": 0.01
    },
    {
      "name": "I3 K Factor",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 274,
      "type": "int16",
      "access": "R",
      "unit": "A",
      "scale": 0.01
    },
    {
      "name": "I1 Crest Factor",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 275,
      "type": "int16",
      "access": "R",
      "unit": "A",
      "scale": 0.01
    },
    {
      "name": "I2 Crest Factor",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 276,
      "type": "int16",
      "access": "R",
      "unit": "A",
      "scale": 0.01
    },
    {
      "name": "I3 Crest Factor",
      "group": "PF/THD/Kfactor",
      "area": "holding",
      "address": 277,
      "type": "int16",
      "access": "R",
      "unit": "A",
      "scale": 0.01
    },
    {
      "name": "PO U1-Flck N",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1000,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Flck N1",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1001,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Flck N",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1002,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Flck N1",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1003,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Flck N",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1004,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Flck N1",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1005,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO Freq N",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1006,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO Freq N1",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1007,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO Freq N2",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1008,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-MAG N",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1009,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-MAG N1",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1010,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-MAG N",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1011,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-MAG N1",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1012,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-MAG N",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1013,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-MAG N1",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1014,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO Uunbal N",
      "group": "EN50160 Modbus 1",
      "area": "holding",
      "address": 1015,
      "type": "uint16",
      "access": "R",
      "unit": "%"
    },
    {
      "name": "PO Uunbal N1",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1016,
      "type": "uint16",
      "access": "R",
      "unit": "%"
    },
    {
      "name": "PO U1-MSignal N",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1017,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-MSignal N1",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1018,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-MSignal N",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1019,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-MSignal N1",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1020,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-MSignal N",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1021,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-MSignal N1",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1022,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Hrm N",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1023,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Hrm N1",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1024,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Hrm N2",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1025,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Hrm N",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1026,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Hrm N1",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1027,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Hrm N2",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1028,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Hrm N",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1029,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Hrm N1",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1030,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Hrm N2",
      "group": "EN50160 Modbus 2",
      "area": "holding",
      "address": 1031,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Inthrm N",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1032,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Inthrm N1",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1033,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Inthrm N",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1034,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Inthrm N1",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1035,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Inthrm N",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1036,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Inthrm N1",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1037,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N11",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1038,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N12",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1039,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N13",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1040,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N14",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1041,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N21",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1042,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N22",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1043,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N23",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1044,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO V1-Dip N24",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1045,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N31",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1046,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N32",
      "group": "EN50160 Modbus 3",
      "area": "holding",
      "address": 1047,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N33",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1048,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N34",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1049,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N41",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1050,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N42",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1051,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N43",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1052,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N44",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1053,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N51",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1054,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N52",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1055,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N53",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1056,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N54",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1057,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N61",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1058,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N62",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1059,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N63",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1060,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Dip N64",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1061,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N11",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1062,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N12",
      "group": "EN50160 Modbus 4",
      "area": "holding",
      "address": 1063,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N13",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1064,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N14",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1065,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N21",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1066,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N22",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1067,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N23",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1068,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N24",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1069,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N31",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1070,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N32",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1071,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N33",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1072,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N34",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1073,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N41",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1074,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N42",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1075,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N43",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1076,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N44",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1077,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N51",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1078,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N52",
      "group": "EN50160 Modbus 5",
      "area": "holding",
      "address": 1079,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N53",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1080,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N54",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1081,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N61",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1082,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N62",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1083,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N63",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1084,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Dip N64",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1085,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N11",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1086,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N12",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1087,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N13",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1088,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N14",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1089,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N21",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1090,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N22",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1091,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N23",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1092,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N24",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1093,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N31",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1094,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N32",
      "group": "EN50160 Modbus 6",
      "area": "holding",
      "address": 1095,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N33",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1096,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N34",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1097,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N41",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1098,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N42",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1099,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N43",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1100,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N44",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1101,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N51",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1102,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N52",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1103,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N53",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1104,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N54",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1105,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N61",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1106,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N62",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1107,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N63",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1108,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Dip N64",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1109,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Intrpt N1",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1110,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Intrpt N2",
      "group": "EN50160 Modbus 7",
      "area": "holding",
      "address": 1111,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Intrpt N3",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1112,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Intrpt N1",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1113,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Intrpt N2",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1114,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Intrpt N3",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1115,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Intrpt N1",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1116,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Intrpt N2",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1117,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Intrpt N3",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1118,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N11",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1119,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N12",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1120,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N13",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1121,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N14",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1122,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N15",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1123,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N21",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1124,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N22",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1125,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N23",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1126,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N24",
      "group": "EN50160 Modbus 8",
      "area": "holding",
      "address": 1127,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N25",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1128,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N31",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1129,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N32",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1130,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N33",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1131,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N34",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1132,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U1-Ovlt N35",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1133,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N11",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1134,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N12",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1135,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N13",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1136,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N14",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1137,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N15",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1138,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N21",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1139,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N22",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1140,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N23",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1141,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N24",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1142,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N25",
      "group": "EN50160 Modbus 9",
      "area": "holding",
      "address": 1143,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N31",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1144,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N32",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1145,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N33",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1146,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N34",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1147,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U2-Ovlt N35",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1148,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N11",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1149,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N12",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1150,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N13",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1151,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N14",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1152,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N15",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1153,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N21",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1154,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N22",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1155,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N23",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1156,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N24",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1157,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N25",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1158,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N31",
      "group": "EN50160 Modbus 10",
      "area": "holding",
      "address": 1159,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N32",
      "group": "EN50160 Modbus 11",
      "area": "holding",
      "address": 1160,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N33",
      "group": "EN50160 Modbus 11",
      "area": "holding",
      "address": 1161,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N34",
      "group": "EN50160 Modbus 11",
      "area": "holding",
      "address": 1162,
      "type": "uint16",
      "access": "R"
    },
    {
      "name": "PO U3-Ovlt N35",
      "group": "EN50160 Modbus 11",
      "area": "holding",
      "address": 1163,
      "type": "uint16",
      "access": "R"
    }
  ]
}