MBMap Registry
  1. Manufacturers
  2. Klemsan

Klemsan

4 device maps · 1,425 registers · klemsan.ir

  • Verified 0
  • Official 0
  • Unofficial 4

Devices

ModelDescriptionStatusProtocolRegisters
KLEA3-phase energy analyzer, Modbus RTU RS-485. All 32-bit IEEE 754 float or 32-bit/64-bit int; each 32-bit value = 2 Modbus words (addr stride +2). FC03 read, FC06/FC10 write. Global at addr 0-26: V-avg, I-total, P/Q/S-total, cosΦ/PF-avg, VLL1/2/3/avg, IN, THDV/THDI-total. Per-phase at 28-150 (L1), 152-274 (L2), 276-398 (L3): V/I/P/Q/S/cosΦ/PF/F/THDV/THDI + voltage harmonics (1st-51st odd, 26 entries) + current harmonics (1st-51st odd, 26 entries). Alarm flags 400-402. Tariff meters T1/T1_1/T1_2/T1_3/T2 import/export active+reactive (32-bit float, kWh/kVArh) at 404-682. Demand peak (current month + 3 prior months) at 684-938. DI counters 940-958. Temp/battery/time 944-948. Alarm statuses (50 alarms) at 960-1358. Archive file numbers 1360-1364. Tariff indices (64-bit double) at 1366-1444. Phase energies (64-bit) at 1458-1694. Digital output logs 1698-1808. DI energy counters 1810-1836. Clear commands 1898-1916. Settings at 2000-2390: CTR/VTR, connection, demand period, energy tariff presets, digital outputs/inputs, baud rate, slave ID, alarm limits (V-LN/LL, I, P, Q, S, IN, PF, cosΦ, F, temp, V-THD, I-THD), device, optional DIO/AO.Unofficial554
KLEA 110P/ECRAS/POWYS3-phase energy analyzer / multimeter, Modbus RTU. Shared map for KLEA 110P, ECRAS 200/220, POWYS 3100/3101. All registers 32-bit (stride +2). Phase measurements 0-58 (V/I/PF/P/Q/S/THDV/THDI per phase, f32 RO); common 60-76 (avg V/I/total P/Q/S/freq/neutral, f32 RO); harmonics 78-268 (odd 1st-31st voltage+current per phase, f32 RO); max 270-346 / min 348-424 (same structure, f32 RO); alarm flags at 426 (u32 bitmask RO, 32 bits); demand 428-458 (current/active/reactive/apparent per phase+total, f32 RO); digital input/hour/interruption counters 460-468 (u32 R/W); energy meters 470-532 (T1/T2 import/export active+reactive, total+per-phase, u32 R/W); device settings 534-590 (CTR/VTR/connection/relay/demand/password/comms/DIO/pulse, u32/f32 R/W); alarm limits 592-652 (V-LN/V-LL/I/IN/cosφ/PF/freq high+low+hyst+delay, f32/u32 R/W); reset commands 1000-1014 (WO); save 2000 (WO); relay control 4000-4004 (WO); counter enable 5000 (WO).Unofficial335
Klea 220P Powys 3121Unofficial50
RAPIDUS3-phase reactive power controller (capacitor bank), Modbus RTU. All registers 32-bit (stride +2). Common data 0-26 (avg V/I, total P/Q/S, avg cosΦ/PF, L-L voltages 1-2/2-3/3-1/avg, neutral I, total THDV/THDI, f32 RO). Per-phase data 28-150 / 152-274 / 276-398: basic (V,I,P,Q,S,cosΦ,PF,freq,THDV,THDI f32) + V harmonics 1,3,...,51 and I harmonics 1,3,...,51 (all f32 RO). Alarm flags at 400 (first 32bits) and 402 (second 32bits, u32 RO). Step variables 404-456: active/available/fixed step flags + switching counts + operation times (u32 RO) for 12 capacitor steps. Tariff meters 458-512 (active/reactive import/export kWh/kVArh, current/last hour/day/month, f32 RO). Demand 514-576 (total+per-phase P/Q/S/I demand values + timestamps, f32/u32 RO). Other 578-582: temperature/battery/time. Alarm log 584-982: 50 events (4 registers each: timestamp u32, ID u32, state u32, value f32). History file numbers 984-988. Step estimated powers 990-1012 (DCM option, f32). Config 2000-2312: network (CTR/VTR/demand period), energy tariff T1 counters, bank (12 steps power/type, bank power/count/discharge), compensation (steps/program/targets/timing/angle), comms (baud/slave), alarm limits for V-LN/V-LL/I/P/Q/S/IN/PF/cosΦ/freq/temp/V-harmonics/I-harmonics/inductive+capacitive energy, auxiliary, learn, device (language/contrast/password/display/serial). Clear commands 1898-1916 (WO). Save 1998 (WO, write 1 to commit config to flash).Unofficial486

Missing a Klemsan device? Request it or add a map.