KACO new energy blueplanet / Powador TL1 and TL3 (SunSpec) Modbus register map

String inverters with Modbus TCP/UDP and RTU using the SunSpec register layout

  • Official
  • 8 registers
  • Modbus TCP and RTU
  • Revision 1 · 2026-11-11
  • Identity: firmware, serial number

Official: Written from the manufacturer's documentation, but not tested on a device yet. Check the map against the manufacturer's documentation before you write to a live device. Tested it? Report a test.

Communication

Protocol
Modbus TCP and RTU
Unit ID
1
TCP port
502
Serial
9600 8E1 · 9600 baud, 8 data bits, even parity, 1 stop bit defaults
Byte / word order
ABCD · bytes big-endian, words high first
Addresses
0-based

Connection values are defaults: the device may be configured differently.

Map

Registers
8 holding registers
Groups
1
Revision
1 · 2026-11-11
Added
()
File
maps/kaco/blueplanet-tl-sunspec.mbmap.json · 4 KB · history
SHA-256
4e7c7099eaf24cc4d2f93225b2cd494146d8b8ec5ff4dd4f9d3e757357dd7a28
Manufacturer
kaco-newenergy.com

Device identity

What a tool can read to check that this map fits the connected device (SPEC.md section 4.7). Registers with a role are read like any other register.

Registers
RoleRegisterAddressTypeValues
Firmware Version holding 40044 string[8]
Serial number Serial number holding 40052 string[16]

Sources and notes

  • Modbus Protocol Application Note - Tx1 and Tx3 Series · version 180730
    Sections 2 to 5; the SunSpec model tables are in SunSpec-Information-Model-Reference-Kaco.xlsx, which is attached to the note and was not available

Source: KACO new energy, Modbus Protocol Application Note, Tx1 and Tx3 Series, version 180730

  • The inverters follow the SunSpec specification: the map starts with 'SunS' at register 40001 (address 40000 on the wire), then the common block, then the models the inverter supports one after another until the end model (DID 0xFFFF). The note names models 1, 101/102/103, 111/113, 112, 122, 123, 129, 130, 135, 136 and 160, depending on the software version.
  • This map holds only the common block, which the note describes. The position of the inverter model depends on the device and the version: walk the chain (each model's length is in its header) and then use the generic maps in maps/sunspec-alliance/ (inverter 101-103 and 111-113) from the position found. The note's own arithmetic puts the next model at 40069; the specification's 66-register common block puts it at 40071, so read the DID to check.
  • Values use SunSpec scale factors: real value = register value x 10^SF. Function 0x03 reads, 0x06 and 0x10 write. Write access has to be enabled in the inverter menu; some settings go to flash and must not be written cyclically.
  • Modbus TCP on port 502 (default); older units have TCP/UDP only through the local GUI, newer ones also Modbus RTU on RS485. The unit identifier addresses auxiliary devices such as a string combiner on newer units. Modbus UDP (packet version 4.0 and later) accepts write commands only.
  • Supported inverters: blueplanet TL1/TL3 (software V2.02 or higher for TL3, V3.00 for TL1) and Powador TL3 (V2.10 or higher).
AreaAddressNameTypeAccessUnitScaleDescription
HR 40000 string[2] R Reads 'SunS' (0x53756E53) on a SunSpec device
HR 40002 uint16 R SunSpec DID, 1
HR 40003 uint16 R 66
HR 40004 string[16] R 'KACO new energy'
HR 40020 string[16] R Inverter name, for example 'Powador 39.0 TL3'
HR 40036 string[8] R Data logger ID string
HR 40044 string[8] R Packet version of the installed software, for example 'V2.10'
HR 40052 string[16] R Serial number set in production