20 device maps · 4,038 registers · entes.com.tr

  • Verified 0
  • Official 16
  • Unofficial 4

Devices

ModelDescriptionStatusProtocolRegisters
EMK-014-phase power quality analyser — per-phase V/I/P/Q/S/CosPhi/PF, voltage & current THD, 3-/4-phase totals, frequency, temperature, energy (IEEE-754 float, Big-Endian).Official63
EMMENTES EMM multimeter series: instantaneous measurements (float32, read as holding registers), a subset of the EMM-04S/EMM-04CS table.Official52
EMM-04S/EMM-04CS3-phase multimeter with Modbus RTU: instantaneous values, min/max/demand with timestamps, network and alarm setup, relays and identification (float32 values, big-endian assumed).Official396
EPC-1212-input pulse concentrator/data logger with Modbus RTU: 64-bit total counters, 8 tariff counters per input, clock and status, communication and counter settings, identification.Official172
EPM 07Unofficial50
EPM-04CS/EPM-06CS3-phase multimeter, Modbus RTU. Phase-neutral voltages at addr 0-4 (V ×0.1); phase currents at 6-12 (A ×0.001); phase-phase voltages at 14-18; cos-phi per phase at 38-42 (★); avg cos-phi at 54-56 (★); frequency at 58 (Hz ×0.01); voltage/current angles at 60-70 (★). Min measurements at 118-136; max at 168-182; max current demand at 204/212/220. Settings: VT/CT ratio at 32766/32769, demand time at 32771, comms at 32777-32784. Alarm functions at 33026+; warning setpoints at 33046+; tripping/releasing times at 33070+.Unofficial90
EPM-07S3-phase multimeter with RS-485 Modbus RTU: voltages, currents, power and cos phi, two energy counter sets, min/max/demand values and setup. Values are 32-bit (two registers), energies 64-bit.Official122
EPR-04S3-phase power meter with RS-485 Modbus RTU: power and cos phi values, two energy counter sets, min/max/demand power values and setup. Values are 32-bit (two registers), energies 64-bit.Official91
EPR04Unofficial50
MPR-3X / MPR-4XMPR34S-11, MPR32S, MPR34S-20, MPR45S, MPR46S, MPR47S, MPR42-OGT, MPR47-SEMPR-3x and MPR-4x series network analyzers, firmware after 1.3.6Official1,007
MPR-3X / MPR-4X (firmware 1.3.6 and earlier)MPR34S-11, MPR32S, MPR34S-20, MPR45S, MPR46S, MPR47S, MPR42-OGTMPR-3x and MPR-4x series network analyzers, firmware 1.3.6 and earlierOfficial910
MPR-53CS3-phase network analyser with RS-485 Modbus RTU: instantaneous values, THD, energy counters, min/max/demand values, pulse and hour counters, 16 setpoints and setup. Values are 32-bit (two registers), energies 64-bit.Official278
MPR-53S3-phase network analyser with RS-485 Modbus RTU: instantaneous values, angles, THD, two energy counter sets, min/max/demand values and setup. Values are 32-bit (two registers), energies 64-bit.Official134
MPR-63MPR-63 network analyser: 16-bit measurement table (0-84, secondary values) and setup registers (256-364). The 32-bit table is in the MPR63 map.Official168
MPR1 SeriesMPR14S, MPR15S-22, MPR16S-21 and MPR17S-23 network analysers: measurement block (addresses 0-160): voltages, currents, power, power factor, angles, analog and temperature inputs and counters.Official81
MPR2 SeriesMPR25S-22, MPR26S-21 and MPR27S-23 network analysers: measurement block (addresses 0-160): voltages, currents, power, power factor, angles, analog and temperature inputs and counters.Official81
MPR3 Series MPR4 SeriesMPR3 and MPR4 series network analysers: measurement block (addresses 0-160), a subset of the MPR-3X/MPR-4X map.Official81
MPR7 SeriesUnofficial50
MPR60MPR60S series network analyser: 32-bit measurement table at 0x4000 (primary values, ratios already applied).Official81
MPR63MPR63 network analyser: 32-bit measurement table at 0x4000 (primary values, ratios already applied). Same table as the MPR60S.Official81

Missing a Entes device? Request it or add a map.