| Model | Description | Status | Protocol | Registers |
|---|---|---|---|---|
| EMK-01 | 4-phase power quality analyser — per-phase V/I/P/Q/S/CosPhi/PF, voltage & current THD, 3-/4-phase totals, frequency, temperature, energy (IEEE-754 float, Big-Endian). | Official | 63 | |
| EMM | ENTES EMM multimeter series: instantaneous measurements (float32, read as holding registers), a subset of the EMM-04S/EMM-04CS table. | Official | 52 | |
| EMM-04S/EMM-04CS | 3-phase multimeter with Modbus RTU: instantaneous values, min/max/demand with timestamps, network and alarm setup, relays and identification (float32 values, big-endian assumed). | Official | 396 | |
| EPC-12 | 12-input pulse concentrator/data logger with Modbus RTU: 64-bit total counters, 8 tariff counters per input, clock and status, communication and counter settings, identification. | Official | 172 | |
| EPM 07 | Unofficial | 50 | ||
| EPM-04CS/EPM-06CS | 3-phase multimeter, Modbus RTU. Phase-neutral voltages at addr 0-4 (V ×0.1); phase currents at 6-12 (A ×0.001); phase-phase voltages at 14-18; cos-phi per phase at 38-42 (★); avg cos-phi at 54-56 (★); frequency at 58 (Hz ×0.01); voltage/current angles at 60-70 (★). Min measurements at 118-136; max at 168-182; max current demand at 204/212/220. Settings: VT/CT ratio at 32766/32769, demand time at 32771, comms at 32777-32784. Alarm functions at 33026+; warning setpoints at 33046+; tripping/releasing times at 33070+. | Unofficial | 90 | |
| EPM-07S | 3-phase multimeter with RS-485 Modbus RTU: voltages, currents, power and cos phi, two energy counter sets, min/max/demand values and setup. Values are 32-bit (two registers), energies 64-bit. | Official | 122 | |
| EPR-04S | 3-phase power meter with RS-485 Modbus RTU: power and cos phi values, two energy counter sets, min/max/demand power values and setup. Values are 32-bit (two registers), energies 64-bit. | Official | 91 | |
| EPR04 | Unofficial | 50 | ||
| MPR-3X / MPR-4XMPR34S-11, MPR32S, MPR34S-20, MPR45S, MPR46S, MPR47S, MPR42-OGT, MPR47-SE | MPR-3x and MPR-4x series network analyzers, firmware after 1.3.6 | Official | 1,007 | |
| MPR-3X / MPR-4X (firmware 1.3.6 and earlier)MPR34S-11, MPR32S, MPR34S-20, MPR45S, MPR46S, MPR47S, MPR42-OGT | MPR-3x and MPR-4x series network analyzers, firmware 1.3.6 and earlier | Official | 910 | |
| MPR-53CS | 3-phase network analyser with RS-485 Modbus RTU: instantaneous values, THD, energy counters, min/max/demand values, pulse and hour counters, 16 setpoints and setup. Values are 32-bit (two registers), energies 64-bit. | Official | 278 | |
| MPR-53S | 3-phase network analyser with RS-485 Modbus RTU: instantaneous values, angles, THD, two energy counter sets, min/max/demand values and setup. Values are 32-bit (two registers), energies 64-bit. | Official | 134 | |
| MPR-63 | MPR-63 network analyser: 16-bit measurement table (0-84, secondary values) and setup registers (256-364). The 32-bit table is in the MPR63 map. | Official | 168 | |
| MPR1 Series | MPR14S, MPR15S-22, MPR16S-21 and MPR17S-23 network analysers: measurement block (addresses 0-160): voltages, currents, power, power factor, angles, analog and temperature inputs and counters. | Official | 81 | |
| MPR2 Series | MPR25S-22, MPR26S-21 and MPR27S-23 network analysers: measurement block (addresses 0-160): voltages, currents, power, power factor, angles, analog and temperature inputs and counters. | Official | 81 | |
| MPR3 Series MPR4 Series | MPR3 and MPR4 series network analysers: measurement block (addresses 0-160), a subset of the MPR-3X/MPR-4X map. | Official | 81 | |
| MPR7 Series | Unofficial | 50 | ||
| MPR60 | MPR60S series network analyser: 32-bit measurement table at 0x4000 (primary values, ratios already applied). | Official | 81 | |
| MPR63 | MPR63 network analyser: 32-bit measurement table at 0x4000 (primary values, ratios already applied). Same table as the MPR60S. | Official | 81 |