Devices

ModelDescriptionStatusProtocolRegisters
ioLogik E1211ioLogik E1211-TRemote Ethernet I/O with 16 digital outputs and a two-port Ethernet switchOfficialTCP141
ioLogik E1212ioLogik E1212-TRemote Ethernet I/O with 8 digital inputs, 8 configurable DIO channels and a two-port Ethernet switchOfficialTCP174
ioLogik E1213ioLogik E1213-TRemote Ethernet I/O with 8 digital inputs, 4 digital outputs, 4 configurable DIO channels and a two-port Ethernet switchOfficialTCP150
ioLogik E1214ioLogik E1214-TRemote Ethernet I/O with 6 digital inputs, 6 relay outputs and a two-port Ethernet switchOfficialTCP116
ioLogik E1240ioLogik E1240-TRemote Ethernet I/O with 8 analog inputs (voltage or current) and a two-port Ethernet switchOfficialTCP99
ioLogik E1241ioLogik E1241-TRemote Ethernet I/O with 4 analog outputs and a two-port Ethernet switchOfficialTCP32
ioLogik E1242ioLogik E1242-TRemote Ethernet I/O with 4 analog inputs, 4 digital inputs, 4 configurable DIO channels and a two-port Ethernet switchOfficialTCP138
ioLogik E1262ioLogik E1262-TRemote Ethernet I/O with 8 thermocouple inputs and a two-port Ethernet switchOfficialTCP91
ioLogik E2210ioLogik E2210-TEthernet micro controller with 12 digital inputs and 8 digital outputs (Click&Go logic)OfficialTCP368
ioLogik E2212ioLogik E2212-TEthernet micro controller with 8 digital inputs, 8 digital outputs and 4 configurable DIO channels (Click&Go logic)OfficialTCP464
ioLogik E2214ioLogik E2214-TEthernet micro controller with 6 digital inputs and 6 relay outputs (Click&Go logic)OfficialTCP300
ioLogik E2240ioLogik E2240-TEthernet micro controller with 8 analog inputs and 2 analog outputs (Click&Go logic)OfficialTCP156
ioLogik E2242ioLogik E2242-TEthernet micro controller with 4 analog inputs and 12 configurable DIO channels (Click&Go logic)OfficialTCP501
ioLogik E2260ioLogik E2260-TEthernet micro controller with 6 RTD inputs and 4 digital outputs (Click&Go logic)OfficialTCP208
ioLogik E2262ioLogik E2262-TEthernet micro controller with 8 thermocouple inputs and 4 digital outputs (Click&Go logic)OfficialTCP248
ioLogik R1210ioLogik R1210-TRS-485 remote I/O with 16 digital inputsOfficialRTU216
ioLogik R1212ioLogik R1212-TRS-485 remote I/O with 8 digital inputs and 8 configurable DIO channelsOfficialRTU312
ioLogik R1214ioLogik R1214-TRS-485 remote I/O with 6 digital inputs and 6 relay outputsOfficialRTU168
ioLogik R1240ioLogik R1240-TRS-485 remote I/O with 8 analog inputs (voltage or current)OfficialRTU112
ioLogik R1241ioLogik R1241-TRS-485 remote I/O with 4 analog outputs (voltage or current)OfficialRTU40
ioThinx 45MR-1600ioThinx 45MR-1600-T16-channel digital input module (PNP, sink) for the ioThinx 4510 adapterOfficialTCP53
ioThinx 45MR-1601ioThinx 45MR-1601-T16-channel digital input module (NPN, source) for the ioThinx 4510 adapterOfficialTCP53
ioThinx 45MR-2404ioThinx 45MR-2404-T4-channel relay output module for the ioThinx 4510 adapterOfficialTCP17
ioThinx 45MR-2600ioThinx 45MR-2600-T16-channel digital output module (sink) for the ioThinx 4510 adapterOfficialTCP51
ioThinx 45MR-2601ioThinx 45MR-2601-T16-channel digital output module (source) for the ioThinx 4510 adapterOfficialTCP51
ioThinx 45MR-2606ioThinx 45MR-2606-T8 digital input and 8 digital output module for the ioThinx 4510 adapterOfficialTCP56
ioThinx 45MR-3800ioThinx 45MR-3800-T8-channel analog input module for the ioThinx 4510 adapterOfficialTCP90
ioThinx 45MR-3810ioThinx 45MR-3810-T8-channel analog input module (voltage) for the ioThinx 4510 adapterOfficialTCP90
ioThinx 45MR-4420ioThinx 45MR-4420-T4-channel analog output module for the ioThinx 4510 adapterOfficialTCP12
ioThinx 45MR-6600ioThinx 45MR-6600-T6-channel RTD input module for the ioThinx 4510 adapterOfficialTCP44
ioThinx 45MR-6810ioThinx 45MR-6810-T8-channel thermocouple input module for the ioThinx 4510 adapterOfficialTCP58
ioThinx 45MR-7210System + field power input monitor ioThinx 45MR slot module. Addresses are module-relative; actual PDU address = slot_base + relative_address. FC03: spStatus (rel 0, system power status WORD), spLowerLimitValue (rel 1-2, f32 lower alarm threshold), spUpperLimitValue (rel 3-4, f32 upper alarm threshold), fpStatus (rel 5, field power status WORD). Write spLowerLimitValue/spUpperLimitValue to configure system power alarm thresholds.Unofficial6